{"product_id":"patient-monitor-pm-lp12a","title":"Patient Monitor PM-LP12A","description":"\u003cp\u003e12 INCH PATIENT MONITOR\u003cbr\u003e\nPM-LP12A\u003cbr\u003e\nNIBP , SPO2 , TEMP, RESP, ECG, ETC02\u003cbr\u003e\nTECHNICAL SPECIFICATIONS Multi-parameter Patient Monitor • CE, ISO13485 • SFDA: Class Ⅱb • Anti-electroshock degree:                           ClassⅠequipment                           (internal power supply) • TEMP\/SpO 2 \/NIBP: BF • ECG\/Resp: CF  Quality Standards and Classification • Adult\/Pediatric\/Neonatal\/Medicine     \/Surgery\/Operating Room\/ICU\/CCU  Application Range • • 12” realcolorTFTscreen Resolution:800×600 • One alarm indicator(yellow\/red) • One working indicator(green) • One battery charge       stateindicator(green) • Three modes in accordance with the      alarm state  Display Operating Environment : • Temperature: 0 ~ 40 ℃ • Humidity: ≤85% • Altitude: -500~4600m Transport and Storage Environment : • Temperature: -20~60 ℃ • Humidity: ≤93% • Altitude: -500~13100m  Environment • AC: 100 ~ 240V, 50Hz\/60Hz • DC: Built-in rechargeable battery • Battery: 5200mAh 11.1V lithium battery      4h operating afterf ull charge(one piece)      5min operating after low battery alarm  Power Requirements • Equipment:     300mm×286mm×155 mm(about);     4.5kg(about) • Package :       350mm ×380 mm × 300mm(about);      6.5kg(about)  Dimension and Weight • Trend diagram\/table: 7x24h • NIBP review: 400 events • Wave review: 100min • Alarm review: 100 alarm events • Support drug concentration titration      analysis  Date Storage • Range: 0 ~ 100% • Resolution: 1% • Precision: 70% ~ 100%: ±2 DIGIT     0% ~ 69%: ±no definition given  SpO2 • Range: 20 ~ 300bpm • Resolution: 1bpm • Precision: ±3bpm   Pulse Rate • Channel 2 • Measure \u0026amp; alarm range: 0 ~ 50 ℃ • Resolution: 0.1 ℃ • Precision (no sensor): ±0.1 ℃   TEMP • Etco2 (Optional) • IBP modular (Optional) • Touch screen (Optional) • Trolley bracket (Optional) • Hanging bracket (Optional) • Monitor recorder (Optional) • Wifi (Optional) • C.O.modular • BIS modular   Optional • 5 Leads: RA, LA, LL, RL, V • Lead mode: Ⅰ,Ⅱ, Ⅲ, aVR, aVL, aVF, V     Increase: ×250，×500，×1000，        ×2000 • Sensitivity: \u0026gt; 200 uV (Peak-to-peak      value) • Input impedance: \u0026gt; 5 ( megohm ) • Bandwidth: Surgery 1 ~ 20 Hz • Monitor 0.5 ~ 40 Hz • Diagnostic 0.05 ~ 130 Hz • CMRR 100dB • Polarization Voltage: ± 300mV • Baseline Recovering Time: After      defibrillation\u0026lt; 3 seconds • Signal Range: 8 mV （Peak-to-peak      value）• Calibrating Signal: 1mV, precision      ±5% • Heart rate range：15-380bmp • Heart rate accuracy:+\/-1%  ECG • Method: RA-LL impedance • Resp Impedance range: 0.3 ~ 3 • Base Impedance range: 200 ~ 4000 • Bandwidth: 0.1 ~ 2.5Hz • Resp rate: Adult 0 ~ 120BrPM • Neonatal\/Pediatric 0 ~ 150BrPM • Resolution: 1BrPM • Precision: ±2 BrPM • Asphyxia Alarm: 10～40 seconds  RESP • Method: Pulse wave oscillometry • Work mode: Manual\/ Auto\/ STAT • Measure interval of auto mode:     1,2,3,4,5,10,15,30,60,90,120,180,     240,480 minute(s) • Measuring Time of STAT Mode: 5       minutes • PR range: 30 ~ 250bpm • Measure \u0026amp; alarm range: Adult                    SYS 40 ~ 270mmHg                    DIA 10 ~ 215mmHg                    MEAN 20 ~ 235mmHg                    Pediatric                    SYS 40 ~ 200mmHg                    DIA 10 ~ 150mmHg                    MEAN 20 ~ 165mmHg                    Neonatal                    SYS 40 ~ 135mmHg                    DIA 10 ~ 100mmHg                    MEAN 20 ~ 110mmHg •  Static pressure range: 0 ~          300mmHg       Precision: ± 3mmHg •  Pressure precision:       Max. average error: ±5mmHg       Max. standard deviation: ±8mmHg •  Overvoltage protection:       Adult 300mmHg       Pediatric 240mmHg       Neonatal 150mmHg  NIBP • Label ART, PA, CVP, RAP, LAP, ICP, P1, P2 • Measuring and alarm range • ART 0 ~ 300 mmHg • PA -6 ~ 120 mmHg • CVP\/RAP\/LAP\/ICP -10 ~ 40 mmHg • P1\/P2 -10 ~ 300 mmHg • Press Sensor • Sensitivity 5 uV\/V\/mmHg • Impedance 300-3000 • Resolution: 1 mmHg • Accuracy: ±2% or ±1mmHg, which great • Actualization interval: about 1 Sec.   IBP • Side\/Main stream • Warm-up time:when the ambient         temperature is 25 ℃, the carbon dioxide        curve(capnogram) can be displayed      within 20\/15 seconds, and all the     specifications can be fulfilled within 2        minutes. • Measurement range:0-150mmHg,      0-19.7%,0-20kPa (at 760mmHg),     atmospheric pressure provided by the       host. • Resolution 0.1mmHg ：0-69mmHg     0.25mmHg： 70-150mmHg • Precision 0-40mmHg： ±2mmHg           41-70mmHg： ±5%（reading）           71-100mmHg： ±8%（reading）           101-150mmHg：±10%（reading）• Respiratory rate range 0- 150 BPM • Respiratory rate accuracy: ±1 BPM   CO2 • NIBP cuff \u0026amp; tube • ECG cable \u0026amp; electrodes • SpO2 sensor • TEMP probe • Lithium-ion battery • Power cable • Operator’s manual\u003c\/p\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":67894066708593,"sku":null,"price":29325.0,"currency_code":"ZAR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0790\/3821\/8353\/files\/nando-13222-13225.jpg?v=1793276586","url":"https:\/\/adbluesolutions.myshopify.com\/products\/patient-monitor-pm-lp12a","provider":"My Store","version":"1.0","type":"link"}