{"product_id":"patient-monitor-yonker-12inch-yk-8000b","title":"Patient Monitor Yonker 12inch Yk-8000B","description":"\u003cp\u003eTECHNICAL SPECIFICATIONS Multiparameter Patient Monitor • CE, ISO13485 • SFDA: Class Ⅱb • Anti-electroshock degree:ClassⅠ equipment (internal power supply) • TEMP\/SpO 2 \/NIBP: BF • ECG\/Resp: CF  Quality Standards and Classification • Adult\/Pediatric\/Neonatal（Necllor Spo2\u0026amp;Suntch Nibp）\/Surgery\/ Operating Room\/ICU\/CCU     (Seperated parameter board)  Application Range • 12.1”TFT screen Display Operating environment : • Temperature: 0 ~ 40 ℃ • Humidity: 15% ~ 80% • Pressure: 86.0 kPa ~ 106.0kPa Transport and Storage environment : • Temperature: -20 ~ 55 ℃ • Humidity: 10% ~ 90% • Pressure: 86.0 kPa ~ 106.0kPa  Environment • AC: 100 ~ 240V, 50Hz\/60Hz • DC: Built-in rechargeable battery • Battery: 11.1V 24wh Li-ion battery • 2h operating after full charge • 5min operating after low battery alarm  Power Requirements • Equipment : 305*162*290mm(about) ;       4kg(about) • Package : 380*350*300mm(about) ; 6kg(about)  Dimension and Weight • Trend diagram\/table: 720h • NIBP review: 10000 events • Wave review: 12h • Alarm review: 200 alarm events • Support drug concentration titration analysis  Date Storage • 5 Leads: RA, LA, LL, RL, V • Lead mode: Ⅰ,Ⅱ, Ⅲ, AVR, AVL, AVF, V  ECG • Gain: × 1.25mm\/mV,2.5mm\/mV, • 5.0mm\/mV, 10mm\/mV, • 20mm\/mV (error 5%) • Sweep speed: 6.25mm\/s,12.5mm\/s,25mm\/s, • 50mm\/s (error≤ ±10%) • Bandwidth: Surgery 1 ~ 25 Hz • Monitor 0.5 ~ 40 Hz • Diagnostic 0.05 ~ 130 Hz • Sensitivity: \u0026gt;200 V P-P • CMRR≥ 112dB • Differential Input Impedance: \u0026gt;5M • ohm Electrode Offset Potential ±300mV • Polarization Voltage ≥±500mV • Input Impedance ≥5 M • Calibration Voltage: 1mV± 5%    Max. Mean Error 5mmHg    Max. Standard Deviation: 8mmHg • Overpressure protection: Adult 300mmHg Pediatric 240mmHg Neonatal 150mmHg • ST Segment Range: -2.0mV ~ +2.0mV • Accuracy: Ranging -0.8 mV ～ +0.8mV, measuring error is ±0.02mV or ±10%, The larger prevails.                    No definition for other ranges. ST Segment • Method: impedance between RA-LL • Resp Impedance range: 0.3 ~ 3 • Base Impedance range: 200 ~ 4000 • Bandwidth: 0.3 ~ 2.5Hz • Gain: × 0.25, × 0.5, × 1, × 2, × 4 • Resp rate:Measurement Range            Adult 0 ~ 120BrPM           Neonatal\/Pediatric 0 ~ 150BrPM • Resolution: 1BrPM • Accuracy: 7 ~ 150BrPM ( 2BrPM)            0 ~ 6BrPM (unspecified) • Apnea Alarm: 10 ~ 40s  RESP • Channel 2 • Measure \u0026amp; alarm range: 0 ~ 50 ℃ • Resolution: 0.1 ℃ • Accuracy (no sensor) ±0.1 ℃ (0~50 ℃) （excluding sensor error）TEMP • ECG cable \u0026amp; electrodes • SpO2 sensor • TEMP probe • NIBP cuff \u0026amp; tube • Power cord • Lithium-ion battery • User manual Standard accessories • Etco2 (Optional) • Dual  IBP (Optional) • Nellcor  Spo2 (Optional) • Suntch  Nibp (Optional) • Recorder (Optional) Optional •Measurement range: 0 ~ 100% •Resolution: 1% •Precision: 70% ~ 100%  ±2% 0%～69%：no definition given  SpO2 •Measure\/alarm range: 20 ~ 300bpm •Resolution: 1bpm • Accuracy ±3bpm  Pulse Rate •Method: Oscillometry •Measure mode: Manual, Auto, STAT •Measure interval in auto mode:1~5\/10\/15\/30\/60\/90\/120\/ 180\/240\/480min •Measure period in STAT mode: 5min •Pulse rate range: 40 ~ 240bpm •Measure \u0026amp; alarm range: Adult           SYS 40 ~ 280mmHg DIA 10 ~ 220mmHg MEAN 20 ~ 240mmHg Pediatric     SYS 40 ~ 220mmHg DIA 10 ~ 160mmHg MEAN 20 ~ 170mmHg Neonatal    SYS 40 ~ 135mmHg DIA 10 ~ 100mmHg MEAN 20 ~ 110mmHg • Static pressure measurement Range: 0 ~ 300mmHg Accuracy 3mmHg Resolution: 1mmHg Accuracy:\u003c\/p\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":67894070411377,"sku":null,"price":12650.0,"currency_code":"ZAR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0790\/3821\/8353\/files\/nando-13238-13239.jpg?v=1793276760","url":"https:\/\/adbluesolutions.myshopify.com\/products\/patient-monitor-yonker-12inch-yk-8000b","provider":"My Store","version":"1.0","type":"link"}